73343
DUAL ROOF HEATING TORCH
- Palnik gazowy dekarski z dwiema dyszami. Zasilanie - gaz propan lub propan butan. Urządzenie wyposażone w rękojeść z regulacją płomienia Obciążenie cieplne to 110 kW, a temperatura płomienia wynosi od 1500 do 1800º C. Wąż o długości 5 m.
Roofing burner with two nozzles 73343, designed for professionals covering large areas of roofs with heat-sealed roofing felt. The length of the burner allows to work in a standing position, high thermal efficiency / 2 burners /, perfectly accelerates the work.
The handle has a special valve that closes the gas supply when the burner is put down. This solution results in great savings in gas consumption.
Gas burners are designed for soldering, heating, drying and roofing work. Thanks to power supply by means of cylinders with compressed butane (it is also possible to supply propane-butane gas mixture), it is possible to work in places without energy sources.
The gas burners are designed for soldering, heating, drying and roofing work.
Package contents
- Burner (G3/8"-19)
- Two 60mm diameter nozzles
- Hose 5 m (G3/8"-19, 21.8-14)
How to use
Mount the device according to the instruction manual. Tighten the hose to the assembled device. Tighten the other end of the hose to the gas cylinder.
Check the tightness of the connections by slightly unscrewing the cylinder valve, then apply soapy water to the connections. If gas bubbles appear, turn off the gas supply and tighten the leaking connections. Repeat the procedure until complete gas tightness is ensured
Tighten the gas valve in the cylinder, then unscrew the appliance valve, but only enough to allow the gas outlet. Ignite the gas at the outlet of the cup. To do this, use a special lighter designed for lighting portable gas burners . After about 20 seconds, press the burner lever). If the flame is too short, adjust the gas pressure with the burner valve. After releasing the lever, the flame will return to economy mode.
After finishing work, turn off the cylinder valve, and then, after the flame is extinguished, set aside (put down) the burner on a non-flammable surface to cool down. After cooling down, proceed with maintenance.
Details of installation, operation and maintenance of the device in the attached instruction manual.
Usage warnings:
The device should only be used with reusable containers containing technical butane gas, equipped with a threaded connection.Use only in well-ventilated rooms.
Please read the instructions before using this device.