Alternating voltage
6-1000 V a.c.
Direct voltage
6-1000 V d.c.
Resistance
0 -1999 Ω
Regularity
50-400 Hz
Continuity test
0-400 MΩ
Phase sequence test
yes
Voltage detection
yes, mechanical
Polarity detection
yes, full range
Measurement accuracy
± (3% + 5)
Reaction time
<1 (LED lights), ≤1 (LCD display) s
Dimensions
280x74x34 mm
Display type
LCD
Display resolution
1 V a.c./V d.c.
Display range
1999
LED display thresholds
12, 24, 50, 120, 230, 400, 690, 1000 V a.c./V d.c..
Auto measurement range
yes
RCD tripping
~30 mA / 230 V
Max. measurement duration
30 s
Regeneration time (time between consecutive RCD tests)
240 s
Low impedance voltage test mode
yes, approx. 7kΩ (to eliminate noise)
Peak current Is (load)
150 mA
Impedance / peak current
350 kΩ / Is <3.5 mA (does not trigger RCD)
Bell ring
yes
Automatic start-up
≥12 V a.c./V d.c. (LED indicators), ≥6 V a.c./V d.c. (LCD display)
Power supply
battery
cell type
2x1.5V; AAA
Working temperature range
-10 ~ +50 ˚C
Operating relative humidity Rh
<85 %
Storage temperature
-10 ~ +50 ˚C
Protection grade
IP64
Weight
285 g
Application
electric
Symbol
YT-28330








Bipolar voltage tester in a solid housing with flexible cables in silicone insulation. Detects and measures AC and DC voltages in the range of 6 to 1000 V. The result is indicated on the LCD display and via LED indicators. The tester also allows you to:
- check the phase rotation sequence in three-phase systems
- check the voltage in low impedance mode (to eliminate noise)
- test the operation of RCD switches with a rated current of 30 mA or less
- perform circuit continuity test and measure resistance up to 1999 ohms
Measurements in low light conditions are facilitated by the built-in LED flashlight. Measurement safety is supported by a solid and sealed housing with IP64 standard. The set includes screw-on probe caps to facilitate measurements in sockets. The meter meets the requirements of CAT III 1000 V / CAT IV 600 V surge protection categories.
- DC voltage measurement: 6-1000 V d.c.
- AC voltage measurement: 6-1000 V a.c.
- Resistance measurement: 0-1999 Ω
- Frequency measurement: 50-400 Hz
- Circuit continuity test: 0-400 MΩ
- Measurement accuracy: ± (3% + 5)
- Impedance (peak current): 350 kΩ / Is <3.5 mA (does not trigger RCD)
- Response time: <1 s (LED indicators), ≤1 s (LCD display)
- Automatic activation: ≥12 V a.c./V d.c. (LED indicators), ≥6 V a.c./V d.c. (LCD display)
- Dimensions: 280 x 74 x 34 mm
- Display: LCD
- Screen resolution: 1 V a.c./V d.c.
- LED display thresholds: 12, 24, 50, 120, 230, 400, 690, 1000 V a.c./V d.c.
- RCD triggering: ~30 mA / 230 V
- Max. measurement duration: 30 s
- Regeneration time (for next RCD test): 240 s
- Power supply: 2 AAA 1.5 V batteries
- Operating and storage temperature: -10 ~ +50˚C
- Relative humidity: <85%
- Weight: 285 g
- Protection class: IP64